Layout classes, according to which the individual layout parameters are classified, were created to categorize the production categories and expenses. These parameters apply to a PCB thickness of ≤1.5 mm. Other parameters apply for other thicknesses.

You are welcome to visit us again. We will regularly expand and revise these pages.

Recommendations

Property Rough Standard Fine Finest High End
Distances a ≥ 0,2 mm ≥ 0,15 mm ≥ 0,125 mm ≥ 0,1 mm ≥ 0,075 mm
Trackwidth b ≥ 0,2 mm ≥ 0,15 mm ≥ 0,125 mm ≥ 0,1 mm ≥ 0,075 mm
Via diameter d ≥ 0,3 mm ≥ 0,25 mm ≥ 0,2 mm ≥ 0,1 mm ≥ 0,1 mm
Pad diameter dy ≥ 0,7 mm ≥ 0,5 mm ≥ 0,4 mm ≥ 0,3 mm ≥ 0,2 mm
Outer restring D ≥ 0,2 mm ≥ 0,15 mm ≥ 0,15 mm ≥ 0,125 mm ≥ 0,1 mm
Inner restring ≥ 0,2 mm ≥ 0,2 mm ≥ 0,175 mm ≥ 0,15 mm ≥ 0,125 mm
Outer copper thickness ≤ 70μm ≤ 40μm ≤ 35μm ≤ 30μm ≤ 20μm
Inner copper thickness ≤ 70μm ≤ 35μm ≤ 35μm ≤ 18μm ≤ 12μm

Actually, these recommendations no longer represent the technological limits. As the name suggests, they are merely recommendations intended to facilitate problem-free production.

If you want or need to fall below individual values, please discuss this with the manufacturer in each individual case.